SICP (Serial Interface Communication Protocol) is the control protocol of Philips professional displays, available over the network on TCP port 5000. The Weble IoT Universal Gateway Philips SICP driver controls Philips displays from the box: backlight on and off, speaker and audio volume, LED strip colour, and restart.
Typical use: switch the digital signage displays of a building off at night and on in the morning, or light the LED strip of a meeting room display according to the room status.
Driver key:
sicp— listed as Philips SICP under IoT in Gateway driver. Licence: required, contact support@weble.ch. Platforms: Linux and Windows.
5000 unless changed.192.168.1.80 (add :<port> if the display does not use port 5000).…/backLight, …/volume, …/ledStrip, …/reboot). Write 0 to %sicp:192.168.1.80/backLight to switch the backlight off.
Name, Cluster ID and Description are common to all drivers: see Gateways. The driver has no other gateway parameter.
{}
%sicp:<host>[:<port>][/<command>[/<sub-command>]] — <port> is 5000 when omitted.
| Address | Value | Writable |
|---|---|---|
%sicp:<host> |
The display (created by you). | No |
…/backLight |
1 = backlight on, 0 = off |
Yes |
…/volume |
Object { "speaker": …, "audio": … } |
Yes |
…/volume/speaker |
Speaker output volume, 0 to 100 % | Yes |
…/volume/audio |
Audio output volume, 0 to 100 % | Yes |
…/ledStrip |
Object { "on": …, "red": …, "green": …, "blue": … } |
Yes |
…/ledStrip/on |
1 = LED strip on, 0 = off |
Yes |
…/ledStrip/red, …/green, …/blue |
Colour, 0 to 255 | Yes |
…/reboot |
Write any value to restart the display; shows 1 for 2 s after the command |
Yes |
Examples:
%sicp:192.168.1.80/backLight — backlight of the display at 192.168.1.80.%sicp:192.168.1.81:5000/volume/speaker — speaker volume of another display.%sicp:192.168.1.80/ledStrip — write {"on": 1, "red": 0, "green": 255, "blue": 0} for a green LED strip.| Label | JSON key | Default | Description |
|---|---|---|---|
| Philips host | name |
IP address (and port) of the display, after the %sicp: prefix. Create only the display address. |
|
| Polling | json.polling |
0 |
Read period in ms. 0: the values are read when the display connects and after each write. |
| Description | description |
(set by the driver) | Free text. |
| Log | log |
never | Logging policy, see Log and Store value policies. |
| Property | Value |
|---|---|
| Readable | Yes — at connection and after each write |
| Writable | The command addresses (see 3.1) |
| Created automatically | Yes — the command addresses of each display; deleting the display address deletes them |
| Routable | Yes |
| Loggable | Yes |
Create a Cron address that is 1 from 7:00 to 20:00 on working days and 0 otherwise, and route it to …/backLight of each display.
Route the room occupancy (from the room booking system or a presence detector) to %sicp:<host>/ledStrip with a route function that returns {"on":1,"red":255,"green":0,"blue":0} when the room is busy and {"on":1,"red":0,"green":255,"blue":0} when it is free.
| Symptom | Cause | What to do |
|---|---|---|
Gateway restarts in a loop; log missing license |
No licence for the driver. | Add the licence in Gateways › License manager. |
Display address offline; log … no response to command … (2s timeout) |
Network control not enabled on the display, wrong port, or display unreachable. | Enable network control in the display menu and check the port. |
Write fails with NACK |
The display refused the command (function not available on this model). | Check that the model supports the function. |
| Gateway restarts | No display reachable at all. | Check the network and the displays; the gateway reconnects after the restart. |
To read the driver log: open the gateway log (see Gateways).