Every gateway runs a driver. A driver has three names, which are easy to mix up:
driver of the gateway and used by the Peers API, the REST API, exports and imports (for example virtual, evok, weblesms);$, %M, %bac:, %mqtt:).This page lists them for every driver of the driver list. The driver catalogue describes what each driver does.
When a gateway is created through the API with the name of the list instead of the key, it is refused with a message that gives the key, for example:
unknown driver 'Internal': that is the UI LABEL, not the driver key. Use driver:'virtual'.A key that does not exist givesnot a valid driver key, and a driver that the box cannot run givesdriver '<key>' is not available on this box.
Sorted by name in the driver list. … stands for a driver-specific part: see the driver page. Drivers marked Linux only are not in the list on Windows.
| Name in the driver list | Driver key | Address name | Category in the driver list | Wiki page |
|---|---|---|---|---|
| ADS | ads |
%ads:<symbol>, %ads-raw:… |
Building Automation | ADS (Beckhoff) |
| Amazon AWS IoT Cloud | awsiot |
%aws:<topic> |
IoT | Amazon AWS IoT |
| api | api |
%api… |
System | API |
| Assistant IA | ai |
%ai:<conversation> |
System | AI (assistants) |
| Azure | azure |
%azure:… |
IoT | Microsoft Azure IoT Hub |
| Bacnet IP/MSTP | bacnet |
%bac:<device>/<object>:<instance>[/<property>] |
Building Automation | BACnet |
| Clearblade IoT Core | clearblade |
%ci:… |
IoT | ClearBlade IoT Core |
| Cron | cron |
a cron expression, e.g. 0 */5 * * * * or @daily |
System | Cron |
| CSV | exportCSV |
%csv_data/<name>, %csv_file/<name> |
System | CSV |
| Dali / Dali2 | dali |
%dali:… |
Building Automation | DALI |
| DMX | dmx |
%dmx:… |
Building Automation | DMX |
| eAlarm | ealarm |
%ealarm:… |
Alarming | — |
| Enocean | enocean |
%enocean:… |
IoT | EnOcean |
| ESPA 4.4.4 | espa |
%espa:… (created by the driver) |
Alarming | ESPA 4.4.4 |
| ftp | ftp |
%ftp… |
System | FTP |
| Generic IP | genericip |
%tcp:…, %udp:… |
IoT | Generic IP |
| Google Cloud IoT | googleIOT |
%gi:<topic> |
IoT | — |
| Google Nest | googleNest |
%nest:… |
IoT | — |
| Home-connect | home-connect |
%hc:… |
IoT | — |
| HTTP | http |
%http-get:…, %http-post:…, %http-put:…, %http-patch:…, %http-delete:…, %http-ws:…, %http-file:… |
IoT | HTTP / HTTPS |
| HUE (Philips) | hue |
%hue:… |
IoT | — |
| ICX | icx |
%icx:… |
Alarming | ICX (Commend) |
| IEC 60870-5-104 | iec104 |
%iec104:[<CA>/]<TYPE>/<IOA> |
Building Automation | IEC 60870-5-104 |
| IM whatsapp/telegram | im |
%im:… |
Alarming | IM (WhatsApp / Telegram) |
| Impulse | impulse |
%impulse… |
Building Automation | Impulse |
| Internal | virtual |
$<name> |
System | Internal |
| KNX IP/USB/TP (Windows: KNX IP) | knx |
group address 1/2/3 or 1/2, physical address 1.1.5, %knx:<n> |
Building Automation | KNX |
| LoRaWAN | lorawan |
%lora:… |
Building Automation | LoRaWAN |
| Luxmate | luxmate |
%luxmate:… |
Building Automation | Luxmate (Zumtobel) |
| Luxtronik | luxtronik |
%luxtronik:… |
Building Automation | Luxtronik |
| M-Bus | mbus |
%mbus:<device>[/<record>] |
Building Automation | M-Bus |
| Matter | matter |
%matter:<label>[/<endpoint>/<cluster>/<attribute>] |
Building Automation | Matter |
| MaxComm | maxcomm |
%maxcomm:… |
Building Automation | MaxComm |
| Meteo Matics | meteomatics |
%meteomatics:… |
IoT | Meteomatics |
| Modbus TCP/RTU | modbus |
%M<n>, %MX<n>, %Q<n>, %QX<n>, %M<unit>-<n>, %M<n>.<bit> |
Building Automation | Modbus |
| MQTT broker/client | mqtt |
%mqtt:<topic> |
IoT | MQTT |
| MyStrom | mystrom |
%mystrom:… |
Building Automation | myStrom |
| N2 | n2 |
%n2:[<device>-]<TYPE><object>[.<attribute>] |
Building Automation | N2 (Johnson Controls) |
| Notification Android/IOS | notification |
%push:… |
Alarming | Notification |
| OBIS IEC62056 meters | obis |
%obis:… |
Building Automation | OBIS / IEC 62056 |
| Obix | obix |
%obix… |
IoT | oBIX |
| OPC UA | opcua |
%opc… |
Building Automation | OPC UA |
| Philips SICP | sicp |
%sicp:… |
IoT | Philips SICP |
| Remote Gateway | remote |
the names of the addresses of the remote gateway | System | Remote Gateway |
| SAIA | saia |
%saia_flag:<n>, %saia_reg:<n>, %saia_input:<n>, %saia_output:<n> |
Building Automation | SAIA S-Bus |
| Sauter Vision Center | svc |
%SVC["<object>"]["<property>"], %SVC_alarms… |
Building Automation | Sauter Vision Center |
| Smart-me | smart-me |
%smart-me:… |
IoT | Smart-me |
| SMPP | smpp |
%smpp:… |
Alarming | SMPP |
| SMS | weblesms |
%sms:…, %call:… |
Alarming | SMS |
| SMTP client | smtp |
e-mail address, e.g. alarm@example.com; %imap:… |
Alarming | SMTP |
| SNMP | snmp |
%snmp:<OID or name>, %snmp_trap:… |
Building Automation | SNMP |
| Sonos | sonos |
%sonos:… |
Building Automation | Sonos |
| System (Linux only) | system |
#cpu, #mem, #disk, #network, #uptime… (created by the driver) |
System | System |
| Thies Clima | thiesclima |
%thiesclima:… |
Building Automation | Thies Clima |
| USS | uss |
%uss:<unit>[/<parameter>[/<index>]] |
Building Automation | USS (Siemens drives) |
| VE | ve |
%ve:<serial>[/<field>] (created by the driver) |
Building Automation | VE.Direct (Victron) |
| Velux KLF-200 | velux |
%velux:… |
Building Automation | Velux KLF-200 |
| WBox IO (Linux only) | evok |
%DI1, %DO1, %AI1, %AO1, %RO1, %LED1, %TEMP1, %OW-<id> (created by the driver) |
System | IO |
| Weather (Switzerland, France, Belgium) | previsionMeteo |
%weather:… |
Other | Weather (CH/FR/BE) |
| Zettler | zettler |
%zettler:… (created by the driver) |
Alarming | Zettler |
| Zigbee | zigbee |
%zig:<topic> |
IoT | Zigbee |
| Zwave | zwave |
%zw:… (created by the driver) |
Building Automation | Z-Wave |
Some drivers need a licence option on the gateway: DMX, ESPA 4.4.4, Luxtronik, MaxComm, Philips SICP, Sauter Vision Center, Sonos, Thies Clima, USS and Z-Wave. Without it the gateway does not connect and its crash log reads missing license. See Licences.
The following drivers create their addresses themselves; Insert address is not available in their address table:
system) — metrics and controls of the box;evok) — inputs and outputs of the gateway hardware;ve) — one address tree per Victron device, as frames arrive;zettler) — events and states of the fire panel;zwave) — one address tree per included device;espa) — last message and status.Other drivers can create addresses on top of the ones you insert, for example when they discover devices or receive new topics: see each driver page.
Project-specific drivers are in the driver list but only work with a setup provided for a project: Altis (altis, Linux only), OZW Siemens (ozw, Linux only) and Synaptiq (synaptiq). Contact support@weble.ch before using them.
Private drivers (🔒 in the catalogue) are not in the driver list by default. They appear when your licence includes them or when a gateway using them already exists on the device; otherwise Weble support can enable them. Contact support@weble.ch.
The driver UI (ui, address names %ui:…, category System) has no page: contact support@weble.ch before using it.