How to read this page. Each entry is a release of the IoT Universal Gateway software, named after its revision number (rNNN) and its date. Major versions are flagged in the title (9.0 = r718, 9.1 = r722). Releases r705 and older are in the Release notes archive.
softwareUpdate_vNNN.wu file linked under the release, click offline in the same window and select the file. All files are listed at https://www.weble.ch/iot/releases/. The full procedure is in Software update.Windows download: https://www.weble.ch/downloads/iot-weble.exe
Linux download: https://www.weble.ch/iot/releases/softwareUpdate_v725.wu or online from the webinterface.
fixes
M-Bus: the secondary address scan no longer misses meters that stop answering for a few seconds after a large collision. A branch that stays silent just after a collision is probed again a few seconds later (test bus of 12 meters, Fast profile: 8 found before, 12 after).
M-Bus: change primary address now reports an explicit error when the meter acknowledges the command but keeps its address.
Backup: fixed the web server restart and the truncated snapshots on boxes with an older system (Debian 9). Affected: releases 722 and 723.
Backup: no longer writes on the data disk, so it also works when the SD card is read-only.
Restore: fixed a failure that could leave the box without its configuration after restoring a backup.
Restore: fixed the error "unexpected end of file" with backups that contain zip files.
Restore with the network option: the network configuration of the backup is applied once and is not applied again at the next restart.
Network settings with automatic rollback: cancelling a change removes the pending rollback, and a refused change no longer leaves a rollback armed. Fixes a network configuration that came back different after a restart.
Login protection: the limit on failed attempts now applies to every login path.
Factory reset: a box delivered with a factory password (printed on its label) goes back to that password.
Cron, OBIS and notification drivers: an invalid entry no longer stops the driver. The error is shown on the address.
SMPP: passwords are no longer written in the logs.
Gateways: a gateway with an invalid configuration now stops at start with an explicit error instead of running with wrong settings.
Routes: messages printed by route functions (filters included) are tagged with the route name and rate-limited. Removes the log flooding seen with some routes.
Logics: fixed the thumbnails in the logic list.
AI assistant: the "gateway has been updated" message no longer appears while editing the assistant of that gateway.
Cloud link: fixed a memory leak in the link between the box and the cloud.
Gateways: fixed a driver form that could be cut off after a start (error "getInterface is not a function").
improvements
M-Bus: the secondary address scan window has a profile list: Medium (default), Fast (adaptive), Slow (safe) and Custom. Custom shows the timing fields. The Scan button stays inside the window in every mode. See M-Bus.
M-Bus: the Medium scan profile waits 2000 ms for an answer (1500 ms before), needed with IP converters that deliver the answers late.
M-Bus: new frame monitor (menu Monitor of an M-Bus gateway). Live decoded list of the frames sent and received: type, function, primary and secondary address, CI field, response delay, errors and raw bytes. Same tool as for Modbus and BACnet. Not available for wireless M-Bus nor with the legacy driver option.
M-Bus: after a successful change of primary address, the meter's addresses are renamed to the new primary address and the old one no longer stays in the list. Routes that still use the old name are counted in the result message.
BACnet: local numeric objects (analog, integer, positive integer, large analog) support the optional properties Min_Pres_Value and Max_Pres_Value (minPresValue, maxPresValue). A BACnet write of Present_Value or Relinquish_Default outside the range is refused with VALUE_OUT_OF_RANGE. Values written by the WBox itself are not limited. An empty value removes the limit.
System page: new option "Web support access" (Webserver configuration). Weble support can open the web interface only while this box is checked. Support logins are recorded. See System configuration.
System page: support access and SSH can be switched on even when the SD card is read-only.
Drivers: new programmable driver (preview). It is not shown in the driver list yet: contact Weble to enable it on your device. Its code and its form are edited in the gateway window (tabs Driver code and Schema code), and it runs in its own process with a memory limit.
Unipi Neuron: the user LEDs are available with the new Unipi system.
Export CSV: the SMB share, domain, user and password can be set in the gateway form.
AI panel: simpler look, clearer display of the remaining credit; permission requests are handled while the assistant is working.
AI assistant: can open a temporary connection to a device behind the box when you allow it (one destination, 30 minutes, administrators only).
Software update: added safeguards when an update fails or is interrupted.
Windows download: https://www.weble.ch/downloads/iot-weble.exe
Linux download: https://www.weble.ch/iot/releases/softwareUpdate_v724.wu or online from the webinterface.
fixes
BACnet: gateways stuck in "pending" after v722. The v722 bacnet.exe (BACnet/SC build)
needs libs/websocket-sharp.dll, which was not shipped; the stack never started and the
gateway restarted every 32 s. Affected: every Linux device updated to v722.
Gateways: after changing a gateway's type (Modbus TCP slave ↔ master, RTU ↔ TCP) or a
remote gateway's target, the address tables, tabs and form show the new type as soon as
the "has been updated" dialog is closed. Previously the old columns stayed.
Remote gateway: the target gateway list loads again when the stored password is
encrypted (it returned unknown_account before).
AI assistant: address updates from the assistant no longer fail on the internal
validateJson flag (SQLite "no column named validateJson").
AI relay: an anonymous session reaching the AI relay no longer crashes the web server.
tinc: key generation no longer blocks the process; configuration directory fix
(r9248/r9250).
M-Bus / Siemens RVD2xx: writes now work on controllers addressed by secondary address
(16 hex), not only by primary address. New record addresses (/N) get a description:
Siemens label [block] for RVD2xx, M-Bus description/unit for other meters. UnitFactor
showed 0 instead of 1 for 10⁰ units (display only). Column headers renamed "RVD2xx
blocks" and "Write enabled" to match the address form.
improvements
Network page: the VPN access widget has been rewritten (start/stop, process probe).
AI panel: a preview button (👁) on downloadable text files opens them in a window
without downloading.
Factory password: the reminder is shown once per login (server-side) instead of once
per browser tab.
Windows download: https://www.weble.ch/downloads/iot-weble.exe
Linux download: https://www.weble.ch/iot/releases/softwareUpdate_v723.wu or online from the webinterface.
new
AI assistant on every device: the AI button is now always shown. The assistant runs on
the device's AI credits (Built-in), on your own API key (Anthropic, OpenAI, DeepSeek),
or is driven by an external MCP client such as Claude Desktop.
AI credits: the balance is shown in the assistant header, and the Credits window details
paid credits, offered credits and the licence. AI credit licences (WL-XXXX-XXXX-XXXX
codes) are added from the assistant or from Administration › Licences, even offline: the
code is attached at the next connection. Weble devices installed before this release
show how to request the 5 $ welcome credit.
AI assistants on gateways (AI driver): each assistant runs on the device's credits or on
its own API key, and the gateway pays for its turns. The model chosen in the assistant's
conversation is saved in its gateway, and ⟳ buttons in the gateway form load the current
model list and saved keys. The driver now needs the AI Connect or FULL licence, like the
other drivers; the trial mode is removed.
Assistant browser: once you allow it, the assistant can open the device's web pages in
its own browser. It acts with your account and your rights, and you can close it at any
time.
BACnet/SC (Secure Connect): BACnet gateways connect over TLS-encrypted WebSocket channels
to a BACnet/SC hub, with an optional failover hub, or act as the hub themselves.
Certificates (.p12, .pem, .cer) are files on the device; VMAC, heartbeat, reconnect delay
and TLS 1.3 can be set per channel. See BACnet.
N2 driver (Johnson Controls Metasys): as master, the device reads and writes N2 devices.
As slave, it emulates N2 Open devices read by an NCM or NAE. A frame monitor is available
from the gateway.
SCEP certificates: Generic IP and MQTT gateways can obtain their TLS certificates from a
SCEP server (RFC 8894). They are renewed automatically 30 days before expiry, and the old
certificate is kept until the new one arrives.
Generic IP: TLS servers can require a client certificate. Pattern addresses
(%tcp:data:regex, or per client with [ip]) extract values from frames. A frame separator
(\n, \r, \xHH…) can be typed in the interface, and the client count includes clients
behind the same NAT.
Web terminal: new dns, tcp and tls commands test name resolution, a TCP port and a TLS
handshake from the device, with nothing extra to install.
improvements
Time: in DHCP time mode, the device uses the NTP servers given by DHCP, or those set in
DATE_NTPS, and resynchronises every 4 hours (DATE_NTP_SYNC_INTERVAL).
Azure IoT: the transport can be chosen: MQTT over WebSocket (443), MQTT (8883), AMQP
(5671), AMQP over WebSocket (443) or HTTPS. Existing gateways keep the transport they use.
Beckhoff ADS: subscriptions and cyclic reads are queued, so hundreds of addresses no
longer flood the PLC router. Changing an address no longer resubscribes all of them.
Disk monitor: enabling or disabling it applies immediately, without a restart.
Language: the interface language you choose is kept after a page reload, and the AI
panel follows it.
AI panel: it opens faster and shows that it is loading. When the AI server does not
answer, the device waits longer between attempts instead of retrying every 10 s, which
kept the local interface busy.
Gateways: saving a gateway yourself, from its form or from the assistant, no longer
shows the "has been updated" popup.
Serial ports: they are selected by their unique ID when the device provides one, so the
right port is kept after a reboot.
Licences page: AI Connect and SMS driver licences are shown by name.
ESPA: pager messages keep their punctuation; only accents are removed, and ß, æ, œ are
converted.
security improvements
Factory password: devices prepared from now on have their own admin password, printed
on their label. A factory reset returns to this password, and a reminder is shown until
it is changed. Devices without a factory password keep the forced password change at
first login.
Web login: repeated failed logins are slowed down, from 5 s up to 5 min, and the login
page shows how long to wait.
SSH access: the SSH port can be changed, or SSH closed to the network, with SSH_PORT in
config.sup.
VPN: communication between the device and the VPN servers is validated more strictly.
AI service: the connection to the AI service verifies the server certificate, uses
renewed keys, and identifies each device with its own token.
Accounts: passwords changed through the assistant follow the same protected path as the
interface.
Programmable driver: user code can only call the device functions the driver allows.
Log server: device authentication and the validation of site identifiers have been
strengthened.
fixes
Cloud logger: logs of an address deleted or renamed in the meantime no longer crash the
logger, nor, in a cluster, all the loggers sharing its process.
Log server: devices still on v720 are accepted again when their licence comment holds
more than the company name.
Hourly reboots: devices no longer reboot every hour when the system login service is
stuck after startup.
Network: a badly indented line in the network configuration file no longer stops the
network service in a loop: the line is attached to the nearest section and reported in
the log.
Modbus: adding or changing addresses while the gateway starts no longer stops the driver.
Beckhoff ADS: a manual read returns the value again instead of nothing.
Zigbee: gateways no longer fail at startup with "e.info is not a function".
Web server: opening /alarms no longer stops the web server, and logout redirects
correctly after config.sup is reloaded.
AI assistant: one failure shows one error message instead of two. Accepting an old
permission card from the history saves the right without restarting an old request. A
model chosen in the main assistant no longer replaces the model of a gateway assistant.
API key mode with no key saved no longer runs on credits.
Windows: USB drives are detected on Windows 11 24H2 and later. Licences installed before
a reinstallation are accepted again.
Licence manager: its texts are translated in English and German.
Windows download: https://www.weble.ch/downloads/iot-weble.exe
Linux download: https://www.weble.ch/iot/releases/softwareUpdate_v722.wu or online from the webinterface.
new
Generic IP driver: a new driver sends and receives raw data as a TCP or UDP client or
server. TCP connections can use TLS, with certificates uploaded by hand or obtained and
renewed automatically through SCEP (Linux only for now).
SAIA S-Bus: S-Bus now works over a serial line (RS-232/RS-485), and a gateway can act as
an S-Bus station that answers a master's reads and writes over UDP or serial. A live
telegram monitor is available from the gateway menu, and the "Unit ID" field is now
called "Station".
Siemens RVD2xx over M-Bus: the new "RVD2xx blocks" option lets you choose which data
blocks to read. You can also write values such as setpoints once "Write enabled" is
turned on for the controller's address, and each write is checked by reading it back.
Both need the gateway's "Legacy driver" option turned off: it is off on new M-Bus
gateways but may still be on for older ones.
BACnet trend logs: a new "Trend view" shows a chart of a local trend log. Trend logs
that have a notification class can send buffer-ready notifications, so a BACnet
supervisor knows when to fetch them.
BACnet proxy: the new "Alarms from routes" gateway option makes the alarm state of local
objects come only from routes.
Beckhoff ADS: the new "Min. CycleTime" option allows refresh rates faster than 1 s (down
to 100 ms). Each address also has a new read mode: auto, subscribe or polling.
HTTP driver file tree: files can now be downloaded, and folders download as a .zip.
Uploads accept files up to 100 MB, show progress and never leave a partial file behind.
Log server alarms: a device whose connection keeps dropping and coming back now raises a
"flapping" alarm. No-data alarms only count silence while the device and its gateway are
connected and stable, so an outage no longer causes a flood of alarms.
improvements
MQTT: the new "Publish only" address option handles topics the broker does not let you
subscribe to, such as Azure IoT Hub telemetry.
Performance: servers with many connected devices use much less CPU and send fewer bursts
of messages at startup and after reconnections.
AI assistant panel: the permissions button shows which rights are granted. Each tool
call shows when it ran, and you can download files the assistant leaves on the device
straight from the chat.
DALI: the built-in DALI interface is now supported. "Extend" commissioning only
addresses new ballasts instead of re-initialising every ballast on the line.
Altis and OZW (Siemens): syncing the project from git is more reliable, and damaged
copies are downloaded again automatically. Repository credentials no longer appear in
the Altis log. OZW gateways that were in a cluster are moved out of it automatically,
with one driver restart.
HTTP driver web server: changed pages show up quickly, while files that have not changed
stay cached. Serving on a dedicated path now also works when HTTPS is enabled. Files
reached through a link that points outside the web folder are now refused.
Memory: drivers that share a process (cluster) now have a lower combined memory limit. A
cluster that stays above it is restarted.
fixes
Licences: on ARM Linux devices (e.g. Raspberry Pi CM4, Unipi Patron), licences installed
before v720 are accepted again.
Updates: an update no longer fails with "could not stop all before upgrade" when routes
are already stopped. A failed attempt no longer leaves the drivers stopped.
MQTT: a TLS curve you set yourself is used again, which fixes "no shared cipher" errors
with some brokers. Login details and certificates are no longer written to the log.
BACnet: controllers' alarm recipient lists no longer fill up after each driver restart,
which could stop alarms from arriving. Trend logs are no longer emptied on their first
event or when their name, description or notification settings change. They also no
longer write to disk on every record, and answer trend data requests (ReadRange) as the
BACnet standard requires.
Siemens RVD2xx: fixed a request, sent on every read, that could make a controller change
its M-Bus address and stop answering.
Routes: routes with an empty destination no longer try to create it on every event. The
linked-address count is no longer doubled, and destination functions get the correct
source gateway name.
Windows: restarting all services or a single process from the interface now works, and
VPN tunnel routes no longer fail with "IF undefined". Disk monitoring and VPN setup also
work on Windows 11 24H2 and later.
Log server: adding or deleting a site no longer restarts the log server or interrupts
logging, and deleted sites no longer come back. Daily, weekly and monthly aggregates are
now correct after a single recalculation.
AI assistant: it now works on standard installations with no manual setup. The web
server no longer restarts about 15 minutes after the first assistant call. "Allow all"
no longer leaves permission cards behind, and a conversation from another account in the
same browser no longer shows "An error occurred" on every message.
Driver crashes: KNX no longer crashes when an object value is written to a group address
that is not declared. Beckhoff ADS no longer crashes when addresses change after a
subscription was refused.
Store value: this setting now shows readable values ("always", "never" or a duration).
Editing a BACnet property no longer resets it to "always".
Imports: imported route and address files keep accented and special characters. CSV
export gateways can now import addresses from a file.
Windows download: https://www.weble.ch/downloads/iot-weble.exe
Linux download: https://www.weble.ch/iot/releases/softwareUpdate_v721.wu or online from the webinterface.
This update focuses on the reliability of recorded data, more resilient communication after restarts and network interruptions, and a set of driver and interface improvements.
Charts & Recorded Data
Reliability & System
Drivers
Web Interface
Update packages are installed from the box administration page as usual. Recorded data and configuration are preserved.
Windows download: https://www.weble.ch/downloads/iot-weble.exe
Linux download: https://www.weble.ch/iot/releases/softwareUpdate_v720.wu or online from the webinterface.
New integrations
Network
Supervision interface
Access control
Storage & reliability
Field buses & data
Windows download: https://www.weble.ch/downloads/iot-weble.exe
Linux download: https://www.weble.ch/iot/releases/softwareUpdate_v718.wu or online from the webinterface.
recursive browse + "Browse from root"; online-by-default status.parentJsonAutoInsert datatype (recursive, bidirectional child topics from JSON) + notatopic local-topic flag.e5e5) collision detection; new live scan UI (primary/secondary) with counters + device list.no-cache + must-revalidate; robust multi-ETag parsing;closeForce reset in onDisconnect).gateOn/gateOff (ReferenceError + wrong active flags).warn muting all output; unified log reader (gateways/loggers/logics); per-driver anti-spam dedup.on_update / on_change / on_cov <deadband> + min <ms> throttle) → fewer SD writes.current default route on the network interfacegetBuildInfo (dev/prod/Windows detection).Dashboards — value indicators
Dashboards — grids
Forms
FluidOrigin:Achat). Also works directly inside table cells.Custom components
Windows download: https://www.weble.ch/downloads/iot-weble.exe
Linux download: https://www.weble.ch/iot/releases/softwareUpdate_v716.wu or online from the webinterface.
* glob and a field/value path syntax. For example, analog*/description matches every address whose type starts with analog (analogInput, analogOutput, analogValue…) while filtering on the description field. The * can be placed anywhere in the pattern (prefix, suffix, or both, e.g. *temp*), making it easy to narrow large address lists without an exact match.Fallback tunnel transport using two persistent HTTP connections for bidirectional TCP tunneling. Designed to work through restrictive corporate firewalls and HTTP proxies that block WebSocket upgrades and non-standard protocols.
| Protocol | Transport | Port |
|---|---|---|
poll |
HTTP | 80 |
polls |
HTTPS | 443 |
Used as last-resort fallback when ws, wss, http2, and ssh tunnels are unavailable or blocked. Lower throughput than WebSocket due to dual-connection overhead and rotation gaps, but passes through virtually any HTTP-capable network path.
M-Bus: frame address propagation and mismatch detection. Recovery strategy with timeout bumping. Fixed gwInsertAddress batching bug. Error tolerance raised from 3 to 10 consecutive reads before restart. Sending SND_NKE on 5 consecutive timeout.
BACnet events/alarms: forgeEvent command (C# TreatForgeEvent). Writable /events addresses (local=forge, remote=acknowledge). receiveAcknowledge handler. Auto-ack via cov="subscribe + autoack" on NotificationClass addresses. AddListElement/RemoveListElement with fallback for recipientList management. notificationUnsubscribe. recipientMatchesSameDevice with idToBacnetAddressMap cross-resolution. Fixed 22.22.22.22 loopback IP with FixLoopbackAddress() in Program.cs. Complete proxy architecture: ROUTE_VALUES/ROUTE_EVENTS/ROUTE_ACK with bacnet_proxy_mapping JSON file.
IEC 60870-5-104: new pure Node.js zero-dependency module. Full state machine, I/S/U frames, k/w windowing, t0-t3 timers. Monitoring TypeIDs (M_SP, M_DP, M_ME_NA/NB/NC) + commands (C_SC, C_DC, C_SE). CP56Time2a timestamps, SQ=0 and SQ=1 modes. Client with auto-reconnect, multi-connection server. All unit tests and loopback integration test passing. See IEC 60870-5-104.
KNX: fixed DPT16 string encoding — now padded to fixed 14 bytes (encoder was sending a variable number of bytes, incompatible with ETS/EIB). Decoder now stops at first null byte.
--max-semi-space-size=2 (Node 18 default 16 MB brought down to 2 MB) and --no-sparkplug (disables baseline compilation) applied to all PM2 processes and driver spawns on node 18+. No more webserver distinction.manageEthernetInterfaceAsync when isBridged() is true).Windows download: https://www.weble.ch/downloads/iot-weble.exe
Linux download: https://www.weble.ch/iot/releases/softwareUpdate_v714.wu or online from the webinterface.
first_last_ts parameter returns actual timestamps of first/last measurements within aggregated intervalscloud.js after network drops (no more manual restart needed)tick_time + cron logging breaking after address cache updateNo release notes were published for this release.
No release notes were published for this release.
Added mbus siemens rvd25xx.
Added monitor interface for bacnet.
Improved monitor interface for modbus.
Fixed a bug in routing when the destination does not exists and the gateway destination is defined.
fixed syntax for node8
Logged time-series / sensor data waiting to be sent to the database is now automatically saved to disk during connection issues, preventing loss until delivery resumes.
The release notes of r705 (December 2025) back to r405 (July 2021) are in the Release notes archive (2021 to 2025).